STAFF PORTAL / ALARM MAINTENANCE / CHECKLIST
Select a result and add detail where a defect, exclusion or inaccessible item needs explanation.
Confirm monitoring centre and occupants notified before testing
Record panel brand, model, firmware and visible condition
Check system date/time and review event history
Record active faults, bypasses, isolations and trouble indicators
Inspect mains indication, power supply and enclosure tamper
Measure standby battery voltage and charging voltage
Complete battery load test and record result
Test each accessible PIR / motion detector
Test each accessible door and window contact
Test glass-break and other specialist detectors
Test panic and duress devices with agreed response controls
Test keypads, readers, audible indications and display
Test internal sirens
Test external sirens and strobes with site approval
Test configured tamper circuits
Verify alarm transmission paths
Confirm monitoring-centre receipt and event description
Review IP, cellular and dual-path communication status
Review wireless supervision, signal and device battery status
Confirm partitions, areas and arming functions operate
Check available app / cloud health and notifications
Record inaccessible or untested devices
Record defects and recommended corrective actions
Restore all zones, outputs, bypasses and monitoring
Advise monitoring centre and client that testing is complete